6kv XLPE Insulated Unarmoured Power Cable

Model NO.: YJV/YJV22/YJV32
Voltage Rating: 0.6/1 Kv 3.6/6 Kv
No.of Cores: 1-5 Cores
Applicable Standard: IEC60502 IEC60331 DIN BS
Max Working Temp: 90 Degrees
Trademark: JIAPU
Transport Package: Wooden Drum
Specification: IEC, ASTM, DIN, BS, GB, Any standard
Origin: Henan China
HS Code: 8544492100
Model NO.: YJV/YJV22/YJV32
Voltage Rating: 0.6/1 Kv 3.6/6 Kv
No.of Cores: 1-5 Cores
Applicable Standard: IEC60502 IEC60331 DIN BS
Max Working Temp: 90 Degrees
Trademark: JIAPU
Transport Package: Wooden Drum
Specification: IEC, ASTM, DIN, BS, GB, Any standard
Origin: Henan China
HS Code: 8544492100
6kV XLPE Insulated Unarmoured Power Cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Prpperty:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

Specification:


Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

2.5

0.12

1.5

17.6

0.34

0.49

1.2000

0.7270

35

7.0

2.5

0.12

1.5

18.5

0.39

0.60

0.8680

0.5240

50

8.3

2.5

0.12

1.6

20.0

0.46

0.74

0.6410

0.3870

70

9.7

2.5

0.12

1.6

21.5

0.55

0.96

0.4430

0.2680

95

11.3

2.5

0.12

1.7

23.3

0.66

1.23

0.3200

0.1930

120

13

2.5

0.12

1.7

24.8

0.77

1.48

0.2530

0.1530

150

14.6

2.5

0.12

1.8

26.4

0.87

1.77

0.2060

0.1240

185

15.9

2.5

0.12

1.8

28.1

1.01

2.13

0.1640

0.0991

240

18.3

2.6

0.12

1.9

30.9

1.23

2.71

0.1250

0.0754

300

20.4

2.8

0.12

2.0

33.6

1.48

3.32

0.1000

0.0601

400

23.2

3.0

0.12

2.1

37.0

1.81

4.16

0.0778

0.0470

500

26.4

3.2

0.12

2.2

41.1

2.24

5.27

0.0605

0.0366

630

30.1

3.2

0.12

2.3

45.0

2.73

6.62

0.0469

0.0283


2)6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

3.4

0.12

1.5

19.4

0.40

0.55

1.2000

0.7270

35

6.9

3.4

0.12

1.6

20.5

0.45

0.66

0.8680

0.5240

50

8.2

3.4

0.12

1.6

21.8

0.52

0.80

0.6410

0.3870

70

9.7

3.4

0.12

1.7

23.5

0.62

1.03

0.4430

0.2680

95

11.3

3.4

0.12

1.7

25.1

0.73

1.30

0.3200

0.1930

120

12.8

3.4

0.12

1.8

26.8

0.85

1.56

0.2530

0.1530

150

14.2

3.4

0.12

1.8

28.2

0.95

1.85

0.2060

0.1240

185

15.9

3.4

0.12

1.9

30.1

1.10

2.22

0.1640

0.0991

240

18.3

3.4

0.12

2.0

32.7

1.33

2.80

0.1250

0.0754

300

20.4

3.4

0.12

2.0

34.8

1.54

3.39

0.1000

0.0601

400

23.2

3.4

0.12

2.2

38.0

1.87

4.22

0.0778

0.0470

500

26.4

3.4

0.12

2.2

41.5

2.26

5.29

0.0605

0.0366

630

30.1

3.4

0.12

2.4

45.6

2.78

6.67

0.0469

0.0283


3)8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

4.5

0.12

1.6

21.8

0.48

0.63

1.2000

0.7270

35

6.9

4.5

0.12

1.7

22.9

0.54

0.75

0.8680

0.5240

50

8.2

4.5

0.12

1.7

24.2

0.61

0.89

0.6410

0.3870

70

9.7

4.5

0.12

1.8

25.9

0.72

1.13

0.4430

0.2680

95

11.3

4.5

0.12

1.8

27.5

0.84

1.40

0.3200

0.1930

120

12.8

4.5

0.12

1.9

29.2

0.96

1.67

0.2530

0.1530

150

14.2

4.5

0.12

1.9

30.6

1.06

1.96

0.2060

0.1240

185

15.9

4.5

0.12

2.0

32.5

1.22

2.34

0.1640

0.0991

240

18.3

4.5

0.12

2.1

35.1

1.46

2.93

0.1250

0.0754

300

20.4

4.5

0.12

2.1

37.2

1.68

3.52

0.1000

0.0601

400

23.2

4.5

0.12

2.2

40.2

2.00

4.35

0.0778

0.0470

500

26.4

4.5

0.12

2.3

43.9

2.43

5.45

0.0605

0.0366

630

30.1

4.5

0.12

2.4

47.8

2.93

6.83

0.0469

0.0283


4)12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

6.9

5.5

0.12

1.7

24.9

0.62

0.83

0.8680

0.5240

50

8.2

5.5

0.12

1.8

26.4

0.70

0.98

0.6410

0.3870

70

9.7

5.5

0.12

1.8

27.9

0.80

1.21

0.4430

0.2680

95

11.3

5.5

0.12

1.9

29.7

0.94

1.50

0.3200

0.1930

120

12.8

5.5

0.12

1.9

31.2

1.05

1.77

0.2530

0.1530

150

14.2

5.5

0.12

2.0

32.8

1.17

2.07

0.2060

0.1240

185

15.9

5.5

0.12

2.0

34.5

1.33

2.45

0.1640

0.0991

240

18.3

5.5

0.12

2.1

37.1

1.57

3.04

0.1250

0.0754

300

20.4

5.5

0.12

2.2

39.4

1.81

3.66

0.1000

0.0601

400

23.2

5.5

0.12

2.3

42.4

2.14

4.49

0.0778

0.0470

500

26.4

5.5

0.12

2.4

46.1

2.58

5.61

0.0605

0.0366

630

30.1

5.5

0.12

2.4

49.8

3.10

6.99

0.0469

0.0283


5)18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

50

8.2

8.0

0.12

2.0

31.8

0.95

1.23

0.6410

0.3870

70

9.7

8.0

0.12

2.0

33.3

1.07

1.47

0.4430

0.2680

95

11.3

8.0

0.12

2.1

35.1

1.21

1.78

0.3200

0.1930

120

12.8

8.0

0.12

2.1

36.6

1.34

2.05

0.2530

0.1530

150

14.2

8.0

0.12

2.2

38.2

1.47

2.37

0.2060

0.1240

185

15.9

8.0

0.12

2.2

39.9

1.64

2.76

0.1640

0.0991

240

18.3

8.0

0.12

2.3

42.5

1.90

3.37

0.1250

0.0754

300

20.4

8.0

0.12

2.4

44.8

2.16

4.01

0.1000

0.0601

400

23.2

8.0

0.12

2.4

47.6

2.52

4.87

0.0778

0.0470

500

26.4

8.0

0.12

2.5

51.3

2.98

6.01

0.0605

0.0366

630

30.1

8.0

0.12

2.6

55.2

3.54

7.43

0.0469

0.0283


6)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

2.5

0.1

2.0

34.6

1.13

1.58

1.2000

0.7270

35

6.9

2.5

0.1

2.1

36.8

1.29

1.92

0.8680

0.5240

50

8.2

2.5

0.1

2.2

39.8

1.51

2.36

0.6410

0.3870

70

9.7

2.5

0.1

2.3

43.2

1.81

3.04

0.4430

0.2680

95

11.3

2.5

0.1

2.4

46.9

2.17

3.87

0.3200

0.1930

120

12.8

2.5

0.1

2.4

50.1

2.53

4.69

0.2530

0.1530

150

14.2

2.5

0.1

2.5

53.3

2.90

5.60

0.2060

0.1240

185

15.9

2.5

0.1

2.6

57.2

3.40

6.77

0.1640

0.0991

240

18.3

2.6

0.1

2.8

63.2

4.12

8.55

0.1250

0.0754

300

20.4

2.8

0.1

3.0

69.0

4.89

10.46

0.1000

0.0601

400

23.2

3.0

0.1

3.4

76.7

6.10

13.18

0.0778

0.0470

500

26.4

3.2

0.1

3.6

85.7

8.10

16.55

0.0605

0.0366


7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

3.4

0.1

2.1

38.7

1.30

1.75

1.2000

0.7270

35

6.9

3.4

0.1

2.2

40.9

1.47

2.22

0.8680

0.5240

50

8.2

3.4

0.1

2.3

43.9

1.70

2.50

0.6410

0.3870

70

9.7

3.4

0.1

2.4

47.3

2.02

3.25

0.4430

0.2680

95

11.3

3.4

0.1

2.5

51.0

2.42

4.12

0.3200

0.1930

120

12.8

3.4

0.1

2.6

54.4

2.79

4.95

0.2530

0.1530

150

14.2

3.4

0.1

2.7

57.6

3.17

5.87

0.2060

0.1240

185

15.9

3.4

0.1

2.8

61.5

3.69

7.06

0.1640

0.0991

240

18.3

3.4

0.1

2.9

66.9

4.38

8.82

0.1250

0.0754

300

20.4

3.4

0.1

3.1

71.8

5.11

10.68

0.1000

0.0601

400

23.2

3.4

0.1

3.3

78.3

6.24

13.32

0.0778

0.0470

500

26.4

3.4

0.1

3.5

86.4

7.63

16.50

0.0605

0.0366


8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

4.5

0.1

2.3

43.9

1.57

2.02

0.9270

0.7270

35

6.9

4.5

0.1

2.4

46.0

1.75

2.38

0.6680

0.5240

50

8.2

4.5

0.1

2.4

48.8

2.00

2.85

0.4936

0.3870

70

9.7

4.5

0.1

2.5

52.3

2.34

3.57

0.3420

0.2680

95

11.3

4.5

0.1

2.6

55.9

2.75

4.45

0.2464

0.1930

120

12.8

4.5

0.1

2.7

59.4

3.16

5.32

0.1955

0.1530

150

14.2

4.5

0.1

2.8

62.6

3.57

6.27

0.1587

0.1240

185

15.9

4.5

0.1

2.9

66.4

4.07

7.45

0.1271

0.0991

240

18.3

4.5

0.1

3.1

72.0

4.82

9.25

0.0976

0.0754

300

20.4

4.5

0.1

3.3

77.0

5.71

11.28

0.0778

0.0601

400

23.2

4.5

0.1

3.4

83.2

6.78

13.86

0.0615

0.0470

500

26.4

4.5

0.1

3.5

91.1

8.20

17.32

0.0487

0.0366


9)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm2

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

-

 

 

 

 

 

 

 

 

35

6.9

5.5

0.1

2.4

50.3

2.00

2.63

0.8680

0.6680

50

8.2

5.5

0.1

2.5

53.3

2.26

3.11

0.6410

0.4936

70

9.7

5.5

0.1

2.6

56.8

2.62

3.85

0.4430

0.3420

95

11.3

5.5

0.1

2.8

60.6

3.07

4.77

0.3200

0.2464

120

12.8

5.5

0.1

2.9

64.1

3.49

5.65

0.2530

0.1955

150

14.2

5.5

0.1

3.0

67.3

3.91

6.61

0.2060

0.1587

185

15.9

5.5

0.1

3.1

71.2

4.44

7.81

0.1640

0.1271

240

18.3

5.5

0.1

3.3

76.8

5.21

9.64

0.1250

0.0976

300

20.4

5.5

0.1

3.3

81.3

6.10

11.66

0.1000

0.0778

400

23.2

5.5

0.1

3.5

87.7

7.20

14.28

0.0778

0.0615

500

26.4

5.5

0.1

3.8

96.0

9.15

17.80

0.0605

0.0487


10)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

50

8.2

8.0

0.1

2.9

64.9

3.02

3.87

0.6410

0.4936

70

9.7

8.0

0.1

3.0

68.4

3.42

4.65

0.4430

0.3420

95

11.3

8.0

0.1

3.1

72.0

3.89

5.59

0.3200

0.2464

120

12.8

8.0

0.1

3.3

75.7

4.39

6.54

0.2530

0.1955

150

14.2

8.0

0.1

3.3

78.7

4.85

7.55

0.2060

0.1587

185

15.9

8.0

0.1

3.4

82.6

5.42

8.79

0.1640

0.1271

240

18.3

8.0

0.1

3.5

88.0

6.22

10.66

0.1250

0.0976

300

20.4

8.0

0.1

3.7

92.9

7.20

12.77

0.1000

0.0778

400

23.2

8.0

0.1

3.9

99.3

8.38

15.46

0.0778

0.0615

500

26.4

8.0

0.1

4.2

107.6

10.15

18.85

0.0605

0.0487
 
 
6kV XLPE Insulated Unarmoured Power Cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Prpperty:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

Specification:


Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

2.5

0.12

1.5

17.6

0.34

0.49

1.2000

0.7270

35

7.0

2.5

0.12

1.5

18.5

0.39

0.60

0.8680

0.5240

50

8.3

2.5

0.12

1.6

20.0

0.46

0.74

0.6410

0.3870

70

9.7

2.5

0.12

1.6

21.5

0.55

0.96

0.4430

0.2680

95

11.3

2.5

0.12

1.7

23.3

0.66

1.23

0.3200

0.1930

120

13

2.5

0.12

1.7

24.8

0.77

1.48

0.2530

0.1530

150

14.6

2.5

0.12

1.8

26.4

0.87

1.77

0.2060

0.1240

185

15.9

2.5

0.12

1.8

28.1

1.01

2.13

0.1640

0.0991

240

18.3

2.6

0.12

1.9

30.9

1.23

2.71

0.1250

0.0754

300

20.4

2.8

0.12

2.0

33.6

1.48

3.32

0.1000

0.0601

400

23.2

3.0

0.12

2.1

37.0

1.81

4.16

0.0778

0.0470

500

26.4

3.2

0.12

2.2

41.1

2.24

5.27

0.0605

0.0366

630

30.1

3.2

0.12

2.3

45.0

2.73

6.62

0.0469

0.0283


2)6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

3.4

0.12

1.5

19.4

0.40

0.55

1.2000

0.7270

35

6.9

3.4

0.12

1.6

20.5

0.45

0.66

0.8680

0.5240

50

8.2

3.4

0.12

1.6

21.8

0.52

0.80

0.6410

0.3870

70

9.7

3.4

0.12

1.7

23.5

0.62

1.03

0.4430

0.2680

95

11.3

3.4

0.12

1.7

25.1

0.73

1.30

0.3200

0.1930

120

12.8

3.4

0.12

1.8

26.8

0.85

1.56

0.2530

0.1530

150

14.2

3.4

0.12

1.8

28.2

0.95

1.85

0.2060

0.1240

185

15.9

3.4

0.12

1.9

30.1

1.10

2.22

0.1640

0.0991

240

18.3

3.4

0.12

2.0

32.7

1.33

2.80

0.1250

0.0754

300

20.4

3.4

0.12

2.0

34.8

1.54

3.39

0.1000

0.0601

400

23.2

3.4

0.12

2.2

38.0

1.87

4.22

0.0778

0.0470

500

26.4

3.4

0.12

2.2

41.5

2.26

5.29

0.0605

0.0366

630

30.1

3.4

0.12

2.4

45.6

2.78

6.67

0.0469

0.0283


3)8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

4.5

0.12

1.6

21.8

0.48

0.63

1.2000

0.7270

35

6.9

4.5

0.12

1.7

22.9

0.54

0.75

0.8680

0.5240

50

8.2

4.5

0.12

1.7

24.2

0.61

0.89

0.6410

0.3870

70

9.7

4.5

0.12

1.8

25.9

0.72

1.13

0.4430

0.2680

95

11.3

4.5

0.12

1.8

27.5

0.84

1.40

0.3200

0.1930

120

12.8

4.5

0.12

1.9

29.2

0.96

1.67

0.2530

0.1530

150

14.2

4.5

0.12

1.9

30.6

1.06

1.96

0.2060

0.1240

185

15.9

4.5

0.12

2.0

32.5

1.22

2.34

0.1640

0.0991

240

18.3

4.5

0.12

2.1

35.1

1.46

2.93

0.1250

0.0754

300

20.4

4.5

0.12

2.1

37.2

1.68

3.52

0.1000

0.0601

400

23.2

4.5

0.12

2.2

40.2

2.00

4.35

0.0778

0.0470

500

26.4

4.5

0.12

2.3

43.9

2.43

5.45

0.0605

0.0366

630

30.1

4.5

0.12

2.4

47.8

2.93

6.83

0.0469

0.0283


4)12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

6.9

5.5

0.12

1.7

24.9

0.62

0.83

0.8680

0.5240

50

8.2

5.5

0.12

1.8

26.4

0.70

0.98

0.6410

0.3870

70

9.7

5.5

0.12

1.8

27.9

0.80

1.21

0.4430

0.2680

95

11.3

5.5

0.12

1.9

29.7

0.94

1.50

0.3200

0.1930

120

12.8

5.5

0.12

1.9

31.2

1.05

1.77

0.2530

0.1530

150

14.2

5.5

0.12

2.0

32.8

1.17

2.07

0.2060

0.1240

185

15.9

5.5

0.12

2.0

34.5

1.33

2.45

0.1640

0.0991

240

18.3

5.5

0.12

2.1

37.1

1.57

3.04

0.1250

0.0754

300

20.4

5.5

0.12

2.2

39.4

1.81

3.66

0.1000

0.0601

400

23.2

5.5

0.12

2.3

42.4

2.14

4.49

0.0778

0.0470

500

26.4

5.5

0.12

2.4

46.1

2.58

5.61

0.0605

0.0366

630

30.1

5.5

0.12

2.4

49.8

3.10

6.99

0.0469

0.0283


5)18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

50

8.2

8.0

0.12

2.0

31.8

0.95

1.23

0.6410

0.3870

70

9.7

8.0

0.12

2.0

33.3

1.07

1.47

0.4430

0.2680

95

11.3

8.0

0.12

2.1

35.1

1.21

1.78

0.3200

0.1930

120

12.8

8.0

0.12

2.1

36.6

1.34

2.05

0.2530

0.1530

150

14.2

8.0

0.12

2.2

38.2

1.47

2.37

0.2060

0.1240

185

15.9

8.0

0.12

2.2

39.9

1.64

2.76

0.1640

0.0991

240

18.3

8.0

0.12

2.3

42.5

1.90

3.37

0.1250

0.0754

300

20.4

8.0

0.12

2.4

44.8

2.16

4.01

0.1000

0.0601

400

23.2

8.0

0.12

2.4

47.6

2.52

4.87

0.0778

0.0470

500

26.4

8.0

0.12

2.5

51.3

2.98

6.01

0.0605

0.0366

630

30.1

8.0

0.12

2.6

55.2

3.54

7.43

0.0469

0.0283


6)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

2.5

0.1

2.0

34.6

1.13

1.58

1.2000

0.7270

35

6.9

2.5

0.1

2.1

36.8

1.29

1.92

0.8680

0.5240

50

8.2

2.5

0.1

2.2

39.8

1.51

2.36

0.6410

0.3870

70

9.7

2.5

0.1

2.3

43.2

1.81

3.04

0.4430

0.2680

95

11.3

2.5

0.1

2.4

46.9

2.17

3.87

0.3200

0.1930

120

12.8

2.5

0.1

2.4

50.1

2.53

4.69

0.2530

0.1530

150

14.2

2.5

0.1

2.5

53.3

2.90

5.60

0.2060

0.1240

185

15.9

2.5

0.1

2.6

57.2

3.40

6.77

0.1640

0.0991

240

18.3

2.6

0.1

2.8

63.2

4.12

8.55

0.1250

0.0754

300

20.4

2.8

0.1

3.0

69.0

4.89

10.46

0.1000

0.0601

400

23.2

3.0

0.1

3.4

76.7

6.10

13.18

0.0778

0.0470

500

26.4

3.2

0.1

3.6

85.7

8.10

16.55

0.0605

0.0366


7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

3.4

0.1

2.1

Dc Worm Gear Motor is a kind of motor widely applied in daily life. For example, the range hood in the kitchen is a typical application.

DC Worm Gear Motor has the following characteristics:
1. Achieve great speed reduction through high gear ratio. Normally reduce the speed as low as 10 rpm.

2. Achieve vertical transform by the worm gear

3. With self-lock function to prevent the back-driving.

However, no matter 3v DC Worm Gear Motor or 6V Dc Worm Gear Motor, the disadvantage is low efficiency, that is about 40%

58Mm Dc Worm Gear Motor mainly includes 58W31ZY

58mm dc worm gear motor

According to the number of stages, 58mm DC Worm Gear Motor has following types:

For 3 stages worm gearbox, we have 49, 74, 101, 218, 290 gear ratios;

For 4 stages worm gearbox, we have 505, 634 gear ratios

Number of stages 3 4
Reduction ratio 49, 74, 101, 218, 290
505, 634
Gearbox Length(L)mm 34 34
Breaking torque(kgf.cm) 15 35
Gearbox efficiency 40% 36%

58mm dc worm gear motor

58mm DC Worm Gear Motor

58Mm Dc Worm Gear Motor,58Mm Dc Motor Gear Motor,58Mm Dc Motor Gear Reduction,58Mm Dc Gear Motor

SHENZHEN DONGMING MOTOR CO., LTD. , http://www.dmdcmotor.com

Posted on